Festo

195748

Bus node CPX-FB6

The Festo 195748 industrial component utilizes the Interbus protocol with a baud rate of 500 or 2000 kbit/s and supports a maximum address volume of 12 bytes each for inputs and outputs. Housed in PA-reinforced and PC materials measuring 50 mm x 107 mm x 50 mm with a weight of 125 g, the unit provides IP65 and IP67 protection classes along with a CRC rating of 1 for low corrosion stress. Featuring product and bus-specific LED displays, DIL switches, and an operating voltage range of 18 to 30 V DC, it operates within an ambient temperature range of -5 to 50 °C. Submit the exact part number, quantity, and application requirements to request a quote.

Request pricing and availabilityCommercial response for your destination and required quantity.
Request a Quote
Manufacturer
Festo
Part number
195748
Data verification
Manufacturer evidence reviewed

For a faster response, include quantity, condition, and delivery destination.

Exact part-number verificationTechnical properties are matched to 195748.
Worldwide sourcingSupport for planned and urgent industrial requirements.
Manufacturer documentationA document is added when the reviewed source provides one.

Verified configuration

Technical Specifications

Protocol
Interbus
Dimensions W x L x H
(including interlinking block) | 50 mm x 107 mm x 50 mm
Product weight
125 g
Ambient temperature
-5 ... 50 °C
Storage temperature
-20 ... 70 °C
Protection class
IP65 | IP67
Corrosion resistance classification CRC
1 - Low corrosion stress
PWIS conformity
VDMA24364-B2-L
Material housing
PA-reinforced | PC
Product-specific LED display
M: Modify, parameterization | PL: load supply | PS: Electronics supply, sensor supply | SF: system error
Bus-specific LED display
BA: bus active | RC: Remotebus Check | RD: Remotebus Disable | TR: Transmit/Receive | UL: Operating voltage
Device-specific diagnostics
Channel and module-oriented diagnostics | Undervoltage modules | Diagnostics memory
Control elements
DIL switches
Fieldbus interface
2 x Sub-D plug for self-assembly | 2x M12x1, 5-pin, B-coded | Sub-D socket and plug, 9-pin
Maximum address volume for inputs
12 Byte
Maximum address volume for outputs
12 Byte
Parameters configuring
Diagnostics behaviour | Fail-safe reaction | Forcing of channels | Signal setup | System parameters
Baud rate
500, 2000 kbit/s
Additional functions
- Acyclic data access via PCP channel | Channel-oriented diagnostics via fieldbus | Start-up parameterization in normal text via fieldbus | System status can be represented using process data | Additional diagnostics interface for operator units
Operating voltage range DC
18 ... 30 V
Nominal operating voltage DC
24 V
Intrinsic current consumption at operating voltage
Typ. 200 mA

Engineering context

Identification and RFQ Guidance

Confirm the exact configuration

Use the manufacturer part number and model code—not appearance alone. Connection, size, material, voltage, pressure, seal, and control options can differ within the same product family.

What to include in your RFQ

Provide quantity, delivery country and ZIP/postal code, required condition, target date, and photographs of the existing nameplate when available.

Technical verification

Our sourcing response is prepared against Festo 195748. Final compatibility remains subject to the machine manufacturer’s requirements and complete application data.