Global industrial sourcing · Houston, Texas+1 417 261 6001 info@mropartsrfq.com
Products/Festo/197179
Reference imageConfirm configuration by manufacturer part number.

Festo

197179

Electrical interface CPV14-GE-IB-8

The Festo 197179 industrial component features a 9-pin Sub-D socket and plug fieldbus interface supporting adjustable baud rates of 500 and 2000 kBit/s via DIL switch, operating within a DC voltage range of 20.4 to 26.4 V at a nominal 24 V. This unit provides 16 inputs, 8 outputs, a CP string extension with up to 32 solenoid coils, and comprehensive diagnostics including status bit monitoring and detection for module absences, overloads, and undervoltages. Rated to IP65 protection class, it functions within an ambient temperature range of -5 to 50 °C and includes polarity protection for all operating voltage connections. Submit the exact part number, quantity, and application requirements for a quote.

Request pricing and availabilityCommercial response for your destination and required quantity.
Request a Quote
Manufacturer
Festo
Part number
197179
Data verification
Manufacturer evidence reviewed

For a faster response, include quantity, condition, and delivery destination.

Exact part-number verificationTechnical properties are matched to 197179.
Worldwide sourcingSupport for planned and urgent industrial requirements.
Manufacturer documentationA document is added when the reviewed source provides one.

Verified configuration

Technical Specifications

CP string extension
Yes | 16 inputs | 8 outputs (or 16 valves)
Fieldbus interface
Sub-D, 9-pin, socket and plug
Device-specific diagnostics
Missing module in CP string | Short circuit / overload, outputs | Short circuit / overload, inputs | Undervoltage, valve manifold (extension) | Undervoltage, output module | Undervoltage, sensor supply power | Undervoltage, valve manifold | Via periphery error:
Configuration support
Icons for CMD software
Maximum number of solenoid coils with string extension
32
Max. number of solenoid coils
16
Polarity protected
For all operating voltage connections
Additional functions
Diagnosis via status bits (inputs)
Baud rate
500, 2000 kBit/s | Adjustment via DIL switch
Operating voltage range DC
20.4 ... 26.4 V
Maximum number of outputs
8 | (16 solenoid coils eliminated)
Maximum number of inputs
16
Nominal operating voltage DC
24 V
Power failure buffering
10 ms
Residual ripple
4 Vss
Current consumption at nominal operating voltage, load
Depending on valve type
Current consumption at nominal operating voltage
Electronics: <= 200 mA | Sensor supply power: depends upon sensor
Storage temperature
-20 ... 70 °C
Protection class
IP65
Ambient temperature
-5 ... 50 °C
Authorization
c UL us - Recognized (OL)
Maximum number of process data bits, outputs
32
Maximum number of process data bits, inputs
32
Fieldbus certification
Interbus club
Electrical isolation, fieldbus interface
Optocoupler
Note regarding fieldbus interface
Remote bus
Bus-specific LED display
BA: bus active | RC: Remotebus Check | RD: Remotebus Disable | UL: operating voltage for Interbus interface
Product-specific LED display
12/14: switching status at valves | Dia: short circuit, load supply, sensor power supply, configuration error | Pow: operating voltage and load supply
Material cover
PA-reinforced
Material seals
CR | NBR
Material housing
Aluminum die cast
Materials note
Conforms to RoHS

Engineering context

Identification and RFQ Guidance

Confirm the exact configuration

Use the manufacturer part number and model code—not appearance alone. Connection, size, material, voltage, pressure, seal, and control options can differ within the same product family.

What to include in your RFQ

Provide quantity, delivery country and ZIP/postal code, required condition, target date, and photographs of the existing nameplate when available.

Technical verification

Our sourcing response is prepared against Festo 197179. Final compatibility remains subject to the machine manufacturer’s requirements and complete application data.