Global industrial sourcing · Houston, Texas+1 417 261 6001 info@mropartsrfq.com
Products/Festo/532270
Reference imageConfirm configuration by manufacturer part number.

Festo

532270

Checkbox CHB-C-P

This Festo industrial component, part number 532270, operates on a nominal DC voltage of 24 V and features an IP64 protection class with dimensions measuring 60 mm in width, 260 mm in height, and 150 mm in length. It incorporates a counting function with a range of 1 to 2 billion, accommodating a maximum part diameter of 25 mm, a minimum part diameter of 0.5 mm, and a minimum part length of 1 mm, while supporting up to 4 type memories and 8 orientations per type memory. The unit includes specific RS 485 encoder connections, an internal 8 A fuse, electronic output limiting of 700 mA, a maximum total PLC connection current of 1 A, quantity pre-selection via CheckKon software, and multiple designated inputs and outputs. Submit the exact part number, quantity, and application requirements for a quote.

Request pricing and availabilityCommercial response for your destination and required quantity.
Request a Quote
Manufacturer
Festo
Part number
532270
Data verification
Manufacturer evidence reviewed

For a faster response, include quantity, condition, and delivery destination.

Exact part-number verificationTechnical properties are matched to 532270.
Worldwide sourcingSupport for planned and urgent industrial requirements.
Manufacturer documentationA document is added when the reviewed source provides one.

Verified configuration

Technical Specifications

Max. part diameter
25 mm
Counting function
Yes
Protection class
IP64
Encoder connection
Per RS 485 specification
Width
60 mm
Height
260 mm
Length
150 mm
Max. part length
Depends upon conveyor belt speed and required resolution
Min. part diameter
0.5 mm
Min. part length
1 mm
Outputs
Good part, correctly oriented | Good part, incorrectly oriented | Incorrect part | Conveyor equipment controls | Conveyor belt controls / standby | “Warning” status message | Error output | Preset counter-setting reached | PLC_Power
Inputs
Build-up sensor 1 | Build-up sensor 2 | Camera - Enable | External error | Counter Reset | External start | External sensor | Key disable | Type Select 0 | Type Select 1 | External teach-in
Max. number of different orientations per type memory
8
Max. Number of type memories
4
Quantity pre-selection
CheckKon software
Counting range
1 - 2 Mrd.
Internal fuse
8 A fuse
Electronic output limiting
700 mA
Max. total current at PLC connection
1 A
Nominal operating voltage DC
24 V
Current consumption with load-free outputs
750 mA
Permissible voltage fluctuation
+/- 15 %
Storage temperature
-20 ... 70 °C
Ambient Conditions
Dry | Shielding against extreme external light sources | Cleanest possible ambient air

Engineering context

Identification and RFQ Guidance

Confirm the exact configuration

Use the manufacturer part number and model code—not appearance alone. Connection, size, material, voltage, pressure, seal, and control options can differ within the same product family.

What to include in your RFQ

Provide quantity, delivery country and ZIP/postal code, required condition, target date, and photographs of the existing nameplate when available.

Technical verification