Global industrial sourcing · Houston, Texas+1 417 261 6001 info@mropartsrfq.com
Products/Festo/534509
Reference imageConfirm configuration by manufacturer part number.

Festo

534509

Electrical interface CPV10-GE-IP-8

The Festo 534509 industrial component features an IP-Link fieldbus interface with incoming and outgoing connections supporting a 2 Mbaud baud rate and operating within a 20.4 to 28.8 V DC voltage range. It accommodates up to 16 solenoid coils with parameter configuration handled via watchdog for coils 1-16 through a read/write register block, alongside complex mode device-specific diagnostics for monitoring valve undervoltage. The unit includes polarity protection for all electrical connections, a 10 ms power failure buffering, and an IP65 protection class rating for environments with a -5 to 50 °C ambient temperature range. Submit the exact part number, quantity, and application requirements to request a formal quote for this Festo component.

Request pricing and availabilityCommercial response for your destination and required quantity.
Request a Quote
Manufacturer
Festo
Part number
534509
Data verification
Manufacturer evidence reviewed

For a faster response, include quantity, condition, and delivery destination.

Exact part-number verificationTechnical properties are matched to 534509.
Worldwide sourcingSupport for planned and urgent industrial requirements.
Manufacturer documentationA document is added when the reviewed source provides one.

Verified configuration

Technical Specifications

CP string extension
No
Fieldbus interface
IP-Link | Incoming, outgoing
Device-specific diagnostics
In complex mode: monitoring of valve undervoltage
Max. number of solenoid coils
16
Parameters configuring
Setting via watchdog for coils 1-16 via read/write register block
Polarity protected
for all electrical connections
Baud rate
2 Mbaud
Operating voltage range DC
20.4 ... 28.8 V
Maximum number of outputs
None
Maximum number of inputs
None
Nominal operating voltage DC
24 V
Power failure buffering
10 ms
Residual ripple
4 Vss
Current consumption at nominal operating voltage, load
Depending on valve type
Current consumption at nominal operating voltage, logic
<= 100 mA
Current consumption at nominal operating voltage
Electronics: <= 100 mA
Storage temperature
-20 ... 70 °C
Relative air humidity
0 - 95 % | non-condensing
Protection class
IP65
Ambient temperature
-5 ... 50 °C
Authorization
c UL us - Recognized (OL)
Compact data model
16 outputs
Complex data model
24 outputs | 24 inputs
Electrical isolation, fieldbus interface
LWL
Bus-specific LED display
Err: faulty data transmission | Run: bus active | UP: operating voltage, valves | US: operating voltage, internal logic
Product-specific LED display
12/14: switching status at valves
Product ID
IE4404
Material cover
PA-reinforced
Material seals
CR | NBR
Material housing
Aluminum die cast
Materials note
Conforms to RoHS

Engineering context

Identification and RFQ Guidance

Confirm the exact configuration

Use the manufacturer part number and model code—not appearance alone. Connection, size, material, voltage, pressure, seal, and control options can differ within the same product family.

What to include in your RFQ

Provide quantity, delivery country and ZIP/postal code, required condition, target date, and photographs of the existing nameplate when available.

Technical verification

Our sourcing response is prepared against Festo 534509. Final compatibility remains subject to the machine manufacturer’s requirements and complete application data.