Global industrial sourcing · Houston, Texas+1 417 261 6001 info@mropartsrfq.com
Products/Festo/538654
Reference imageConfirm configuration by manufacturer part number.

Festo

538654

Command unit CPVSC1-AE16-DN

The Festo part number 538654 is an industrial component featuring dimensions of 78 mm in width, 40 mm in height, and 113 mm in length, alongside a CP string extension supporting 16 inputs and 8 outputs or 16 valves. It utilizes a DeviceNet protocol with an M12x1, 5-pin, A-coded fieldbus interface and accommodates baud rates of 125, 250, and 500 kBit/s adjustable via DIL switch. Integrated device-specific diagnostics cover condition monitoring, short circuits or overloads for inputs and outputs, missing modules, and undervoltage conditions for sensors, outputs, and valve manifolds. Please submit the exact part number, quantity, and application requirements to receive a formal quotation.

Request pricing and availabilityCommercial response for your destination and required quantity.
Request a Quote
Manufacturer
Festo
Part number
538654
Data verification
Manufacturer evidence reviewed

For a faster response, include quantity, condition, and delivery destination.

Exact part-number verificationTechnical properties are matched to 538654.
Worldwide sourcingSupport for planned and urgent industrial requirements.
Manufacturer documentationA document is added when the reviewed source provides one.

Verified configuration

Technical Specifications

Width
78 mm
Height
40 mm
Length
113 mm
CP string extension
16 inputs | 8 outputs (or 16 valves)
Fieldbus interface
M12x1, 5-pin, A coded
Device-specific diagnostics
ConditionMonitoring | Missing module in CP string | Short circuit / overload, outputs | Short circuit / overload, inputs | Undervoltage, valve manifold (extension) | Undervoltage, output module | Undervoltage, sensor supply power | Undervoltage, valve manifold
Communication types
Change of State | Explicit Message | Polling | Strobbed I/O
Configuration support
EDS file and graphic symbol
Max. number of solenoid coils
16
Parameters configuring
Configuring interface for modules and system parameters | Online in run and program mode | In plain text (EDS)
Polarity protected
For all operating voltage connections
Additional functions
Condition Counter
Control elements
DIL switch for setting the CP configuration | rotary switch for setting the station number and baud rate
Baud rate
125, 250, 500 kBit/s | Adjustment via DIL switch
Operating voltage range, DC electronics/sensors
20.4 ... 26.4 V
DC operating voltage, load voltage
20.4 ... 26.4 V
Nominal DC operating voltage, load voltage
24 V
Power failure buffering
20 ms
Protocol
DeviceNet
Residual ripple
4 Vss
Residual ripple, load voltage
4 Vss
Current consumption at nominal operating voltage, load
Depends upon valve type and number of valves
Current consumption at nominal operating voltage
Electronics: <= 200 mA | Sensor supply power: depends upon sensor
Storage temperature
-20 ... 50 °C
Relative air humidity
90% at 50° C | non-condensing
Protection against direct and indirect contact
PELV
Protection class
IP20
to
IEC 60529
Ambient temperature
-5 ... 50 °C

Engineering context

Identification and RFQ Guidance

Confirm the exact configuration

Use the manufacturer part number and model code—not appearance alone. Connection, size, material, voltage, pressure, seal, and control options can differ within the same product family.

What to include in your RFQ

Provide quantity, delivery country and ZIP/postal code, required condition, target date, and photographs of the existing nameplate when available.

Technical verification

Our sourcing response is prepared against Festo 538654. Final compatibility remains subject to the machine manufacturer’s requirements and complete application data.