Checkbox CHB-C-F

The Festo 539076 industrial component operates on a 24 V DC nominal voltage with a permissible voltage fluctuation of +/- 15 % and a current consumption of 750 mA with load-free outputs. Equipped with a counting function, CheckKon software quantity pre-selection, and a counting range of 1 to 2 billion, the unit features 16 type memories with a maximum of 8 different orientations per type memory, an RS 485 encoder connection, and a 4/100 mm camera resolution. It includes specific inputs for build-up sensors, camera enable, external errors, counter resets, external starts, external sensors, key disables, and type selects, alongside outputs for good parts, incorrect parts, conveyor controls, warnings, errors, preset counter limits, and PLC power. Designed for use in ambient temperatures from -10 to 50 °C and storage temperatures from -20 to 70 °C under dry, clean, shielded conditions, this IP64-protected part weighs 2,500 g and integrates an 8 A internal fuse with 700 mA electronic output limiting and a 1 A max total PLC connection current. Submit the exact part number, quantity, and application requirements to request a quote.

Request pricing and availabilityCommercial response for your destination and required quantity.
Request a Quote
Manufacturer
Festo
Part number
539076
Data verification
Manufacturer evidence reviewed

For a faster response, include quantity, condition, and delivery destination.

Exact part-number verificationTechnical properties are matched to 539076.
Worldwide sourcingSupport for planned and urgent industrial requirements.
Manufacturer documentationA document is added when the reviewed source provides one.

Verified configuration

Technical Specifications

Counting function
Yes
Protection class
IP64
Encoder connection
Per RS 485 specification
Outputs
Good part, correctly oriented | Good part, incorrectly oriented | Incorrect part | Conveyor equipment controls | Conveyor belt controls / standby | “Warning” status message | Error output | Preset counter-setting reached | PLC_Power
Inputs
Build-up sensor 1 | Build-up sensor 2 | Camera - Enable | External error | Counter Reset | External start | External sensor | Key disable | Type Select 0 | Type Select 1
Max. number of different orientations per type memory
8
Max. Number of type memories
16
Quantity pre-selection
CheckKon software
Counting range
1 - 2 Mrd.
Internal fuse
8 A fuse
Electronic output limiting
700 mA
Max. total current at PLC connection
1 A
Nominal operating voltage DC
24 V
Current consumption with load-free outputs
750 mA
Permissible voltage fluctuation
+/- 15 %
Storage temperature
-20 ... 70 °C
Ambient Conditions
Dry | Shielding against extreme external light sources | Cleanest possible ambient air
Ambient temperature
-10 ... 50 °C
Product weight
2,500 g
Camera resolution
4/100 mm
Exposure time
128 ... 1,024 µs
Operating distance
95 ... 99 mm
Field of vision
42 - 45 mm
Diagnosis interface
RS 232 interface | 115 Kbaud | M12x1 | 4-pin
Materials note
Free of copper and PTFE

Engineering context

Identification and RFQ Guidance

Confirm the exact configuration

Use the manufacturer part number and model code—not appearance alone. Connection, size, material, voltage, pressure, seal, and control options can differ within the same product family.

What to include in your RFQ

Provide quantity, delivery country and ZIP/postal code, required condition, target date, and photographs of the existing nameplate when available.

Technical verification

Our sourcing response is prepared against Festo 539076. Final compatibility remains subject to the machine manufacturer’s requirements and complete application data.