Global industrial sourcing · Houston, Texas+1 417 261 6001 info@mropartsrfq.com
Products/Festo/541918
Reference imageConfirm configuration by manufacturer part number.

Festo

541918

Command unit CPASC1-AE32-DP

The Festo 541918 industrial component features a Profibus protocol with DPV0 cyclical communication, supporting a baud rate from 9.6 kBit/s to 12 Mbit/s with automatic detection via a 9-pin Sub-D socket fieldbus interface. This unit provides a CP string extension capacity of 32 inputs and 32 outputs, handling a maximum of 32 solenoid coils, and includes a DIL switch for CP configuration alongside a rotary switch for station number and baud rate settings. Comprehensive device-specific diagnostics cover condition monitoring, missing modules in the CP string, short circuits or overloads on inputs and outputs, and undervoltage conditions for sensors, outputs, and valve manifolds. Submit the exact part number, quantity, and application requirements for a formal quote.

Request pricing and availabilityCommercial response for your destination and required quantity.
Request a Quote
Manufacturer
Festo
Part number
541918
Data verification
Manufacturer evidence reviewed

For a faster response, include quantity, condition, and delivery destination.

Exact part-number verificationTechnical properties are matched to 541918.
Worldwide sourcingSupport for planned and urgent industrial requirements.
Manufacturer documentationA document is added when the reviewed source provides one.

Verified configuration

Technical Specifications

Width
90 mm
Height
54 mm
Length
80 mm
CP string extension
32 inputs | 32 outputs
Fieldbus interface
Sub-D, 9-pin, socket
Device-specific diagnostics
ConditionMonitoring | Missing module in CP string | Short circuit / overload, outputs | Short circuit / overload, inputs | Undervoltage, valve manifold (extension) | Undervoltage, output module | Undervoltage, sensor supply power | Undervoltage, valve manifold
Communication types
DPV0: cyclical communication
Configuration support
EDS file and graphic symbol
Max. number of solenoid coils
32
Parameters configuring
Parameterization via GSD file
Polarity protected
For all operating voltage connections
Additional functions
Condition Counter | Tool change function
Control elements
DIL switch for setting the CP configuration | rotary switch for setting the station number and baud rate
Baud rate
9,6 kBit/s ... 12 Mbit/s | Automatic detection
Operating voltage range, DC electronics/sensors
20.4 ... 26.4 V
Load voltage range DC
20.4 ... 26.4 V
Nominal voltage DC
24 V
Power failure buffering
20 ms
Protocol
Profibus
Residual ripple
4 Vss
Residual ripple, load voltage
4 Vss
Current consumption at nominal operating voltage, load
Depends upon valve type and number of valves
Current consumption at nominal operating voltage
Electronics: <= 200 mA | Sensor supply power: depends upon sensor
Corrosion resistance classification CRC
0
Storage temperature
-20 ... 50 °C
Relative air humidity
90% at 50° C | non-condensing
Protection against direct and indirect contact
PELV
Protection class
IP40
to
IEC 60529
Ambient temperature
-5 ... 50 °C

Engineering context

Identification and RFQ Guidance

Confirm the exact configuration

Use the manufacturer part number and model code—not appearance alone. Connection, size, material, voltage, pressure, seal, and control options can differ within the same product family.

What to include in your RFQ

Provide quantity, delivery country and ZIP/postal code, required condition, target date, and photographs of the existing nameplate when available.

Technical verification

Our sourcing response is prepared against Festo 541918. Final compatibility remains subject to the machine manufacturer’s requirements and complete application data.