Electrical interface CPV10-GE-CO3-8

The Festo part number 546204 is an industrial component featuring 1 Tx/Rx PDO, 1 SDO server, and a CP string extension supporting 32 inputs and 32 outputs. It operates on a nominal DC voltage of 24 V within a range of 20.4 to 26.4 V, with adjustable baud rates from 125 to 1000 kbit/s via switch module. The unit provides device-specific diagnostics including Condition Monitoring, short circuit detection, and undervoltage monitoring via emergency message and objects 1001, 1002, and 1003. Submit the exact part number, quantity, and application requirements for a formal quote.

Request pricing and availabilityCommercial response for your destination and required quantity.
Request a Quote
Manufacturer
Festo
Part number
546204
Data verification
Manufacturer evidence reviewed

For a faster response, include quantity, condition, and delivery destination.

Exact part-number verificationTechnical properties are matched to 546204.
Worldwide sourcingSupport for planned and urgent industrial requirements.
Manufacturer documentationA document is added when the reviewed source provides one.

Verified configuration

Technical Specifications

Number of PDOs
1 Tx/Rx
Number of SDOs
1 SDO server
CP string extension
Yes | 32 inputs | 32 outputs
Fieldbus interface
Optional | - 5-pin screw terminal strip | - Socket and plug, M12x1, 5-pin, A coded | - Sub-D, 9-pin, socket
Device-specific diagnostics
ConditionMonitoring | Enhanced CP string diagnostics | Missing module in CP string | Configuration error on CP string | Short circuit, CP string | Short circuit / overload, outputs | Short circuit / overload, inputs | Undervoltage, valve manifold (extension) | Undervoltage, output module | Undervoltage, sensor supply power | Undervoltage, valve manifold | via emergency message and object 1001, 1002, 1003
Communication types
Per DS 401
Configuration support
EDS file and bitmaps
Maximum number of solenoid coils with string extension
48
Max. number of solenoid coils
16
Parameters configuring
Via SDO
Polarity protected
For all operating voltage connections
Additional functions
Condition Counter
Baud rate
125, 250, 500 and 1000 kbit/s | Adjustment via switch module
Operating voltage range DC
20.4 ... 26.4 V
Maximum number of outputs
16 solenoid coils and 32 outputs | 48 valve coils
Maximum number of inputs
32
Nominal operating voltage DC
24 V
Power failure buffering
10 ms
Residual ripple
4 Vss
Current consumption at nominal operating voltage, load
Depending on valve type
Current consumption at nominal operating voltage
Electronics: <= 200 mA | Sensor supply power: depends upon sensor
Corrosion resistance classification CRC
1 - Low corrosion stress
Storage temperature
-20 ... 70 °C
Protection class
IP20 | IP65
Ambient temperature
-5 ... 50 °C
Authorization
c UL us - Recognized (OL)

Engineering context

Identification and RFQ Guidance

Confirm the exact configuration

Use the manufacturer part number and model code—not appearance alone. Connection, size, material, voltage, pressure, seal, and control options can differ within the same product family.

What to include in your RFQ

Provide quantity, delivery country and ZIP/postal code, required condition, target date, and photographs of the existing nameplate when available.

Technical verification

Our sourcing response is prepared against Festo 546204. Final compatibility remains subject to the machine manufacturer’s requirements and complete application data.