The Festo part number 564938 is an industrial component utilizing a thermal heat-loss measuring principle to monitor volume and volumetric flow rate from left to right in a unidirectional flow direction. It operates within a flow measuring range of 50 l/min to 5000 l/min for compressed air as per ISO 8573-1:2010 [7:4:4] or nitrogen, featuring an operating pressure up to 1.6 MPa (16 bar / 232 psi) and an overload pressure of 2 MPa (20 bar / 290 psi). Certified with the RCM compliance mark, c UL us - recognized (OL) status under certificate UL E322346, and CE and UKCA markings per EMC and RoHS directives, it maintains a flow rate accuracy of ±(3% o.m.v. + 0.3% FS) at a nominal temperature of 23 °C within operating and ambient temperatures of 0 °C to 50 °C. Submit the exact part number, quantity, and application requirements to receive a formal quotation.

Request pricing and availabilityCommercial response within one business day for your destination and required quantity.
Request a Quote
Why no listed price?

Industrial and obsolete parts are priced per enquiry: the final price depends on available stock, condition, quantity, and your delivery destination, so a fixed list price would be misleading. Request a quote and we confirm current pricing, lead time, and sourcing options — including hard-to-find and discontinued Festo references — within one business day.

Manufacturer
Festo
Part number
564938
Data verification
Manufacturer evidence reviewed

For a faster response, include quantity, condition, and delivery destination.

Exact part-number verificationTechnical properties are matched to 564938.
Worldwide sourcingSupport for planned and urgent industrial requirements.
Manufacturer documentationA document is added when the reviewed source provides one.

Verified configuration

Technical Specifications

Certication
RCM compliance mark | c UL us - recognized (OL)
CE marking (see declaration of conformity)
As per EU EMC directive | As per EU RoHS directive
UKCA marking (see declaration of conformity)
To UK instructions for EMC | To UK RoHS instructions
Certicate issuing authority
UL E322346
Note on materials
RoHS compliant
Measured variable
Volume | Volumetric ow rate
Flow direction
Unidirectional | From left to right
Measuring principle
Thermal
Method of measurement
Heat loss
Flow measuring range start value
50 l/min
Flow measuring range end value
5000 l/min
Operating pressure
1.6 MPa | 16 bar | 232 psi
Overload pressure
2 MPa | 20 bar | 290 psi
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4] | Nitrogen
Temperature of medium
0 °C...50 °C
Ambient temperature
0 °C...50 °C
Nominal temperature
23 °C
Accuracy of ow rate
±(3% o.m.v. + 0.3% FS)
Zero point repetition accuracy in ± %FS
0.2 %FS
Repetition accuracy margin in ± %FS
0.8 %FS
Temperature co-efficient margin in ± %FS/K
typ. 0.1%FS/K
Pressure inuence of margin in ±%FS/bar
0.5 %FS/b.
Switching output
2 x PNP or 2 x NPN switchable
Switching function
Window comparator or threshold value comparator, adjustable

Engineering context

Identification and RFQ Guidance

Confirm the exact configuration

Use the manufacturer part number and model code—not appearance alone. Connection, size, material, voltage, pressure, seal, and control options can differ within the same product family.

What to include in your RFQ

Provide quantity, delivery country and ZIP/postal code, required condition, target date, and photographs of the existing nameplate when available.

Technical verification

Our sourcing response is prepared against Festo 564938. Final compatibility remains subject to the machine manufacturer’s requirements and complete application data.