Global industrial sourcing · Houston, Texas info@mropartsrfq.com
Products/Festo/565402
Festo 565402 Flow sensor SFAB-600U-HQ10-2SV-M12
Reference imageConfirm configuration by manufacturer part number.

Festo

565402

Flow sensor SFAB-600U-HQ10-2SV-M12

The Festo part number 565402 is an industrial component utilizing a thermal heat loss measuring principle for unidirectional volume and volumetric flow rate monitoring from 6 l/min to 600 l/min. It operates within a pressure range of 0 bar to 10 bar and supports compressed air as per ISO 8573-1:2010 [7:4:4] or nitrogen at a medium and ambient temperature of 0 °C to 50 °C. This RoHS-compliant unit holds RCM and cUL us recognitions, carries CE and UKCA markings for EMC and RoHS directives, and features an accuracy of flow rate of ± (3% o.m.v. + 0.3% FS). Submit the exact part number, quantity, and application requirements to request a quote.

Request pricing and availabilityCommercial response within one business day for your destination and required quantity.
Request a Quote
Why no listed price?

Industrial and obsolete parts are priced per enquiry: the final price depends on available stock, condition, quantity, and your delivery destination, so a fixed list price would be misleading. Request a quote and we confirm current pricing, lead time, and sourcing options — including hard-to-find and discontinued Festo references — within one business day.

Manufacturer
Festo
Part number
565402
Data verification
Manufacturer evidence reviewed

For a faster response, include quantity, condition, and delivery destination.

Exact part-number verificationTechnical properties are matched to 565402.
Worldwide sourcingSupport for planned and urgent industrial requirements.
Manufacturer documentationA document is added when the reviewed source provides one.

Verified configuration

Technical Specifications

Certication
RCM compliance mark | c UL us - Recognized (OL)
CE marking (see declaration of conformity)
As per EU EMC directive | As per EU RoHS directive
UKCA marking (see declaration of conformity)
To UK instructions for EMC | To UK RoHS instructions
Certicate issuing authority
UL E322346
Note on materials
RoHS-compliant
Measured variable
Volume | Volumetric ow rate
Flow direction
Unidirectional | P1 -> P2
Measuring principle
Thermal
Method of measurement
Heat loss
Flow measuring range start value
6 l/min
Flow measuring range end value
600 l/min
Operating pressure
0 MPa...1 MPa | 0 bar...10 bar | 0 psi...145 psi
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4] | Nitrogen
Temperature of medium
0 °C...50 °C
Ambient temperature
0 °C...50 °C
Nominal temperature
23 °C
Accuracy of ow rate
± (3% o.m.v. + 0.3% FS)
Zero point repetition accuracy in ± %FS
0.2 %FS
Repetition accuracy margin in ± %FS
0.8 %FS
Temperature co-efficient margin in ± %FS/K
typ. 0. 1%FS/K
Pressure inuence of margin in ±%FS/bar
0.5 %FS/b.
Switching output
2 x PNP or 2 x NPN switchable
Switching function
Window comparator | Threshold value comparator
Switching element function
N/C contact/N/O contact switchable
Max. output current
100 mA

Engineering context

Identification and RFQ Guidance

Confirm the exact configuration

Use the manufacturer part number and model code—not appearance alone. Connection, size, material, voltage, pressure, seal, and control options can differ within the same product family.

What to include in your RFQ

Provide quantity, delivery country and ZIP/postal code, required condition, target date, and photographs of the existing nameplate when available.

Technical verification