Global industrial sourcing · Houston, Texas info@mropartsrfq.com
Products/Festo/6484
Festo 6484 PE converter PE-1/8-1N-SW
Reference imageConfirm configuration by manufacturer part number.

Festo

6484

PE converter PE-1/8-1N-SW

The Festo part number 6484 is a pneumatic-electric pressure transducer measuring relative pressure within an operating range of 0 MPa to 0.8 MPa (0 bar to 8 bar) and handling a maximum overload pressure of 12 bar. Operating on compressed air conforming to ISO 8573-1:2010 [7:4:4] with a medium and ambient temperature range of 0 °C to 60 °C, this component features a contact-based changeover switch with a fixed hysteresis threshold value, supporting AC and DC operating voltages from 12 V to 250 V. It conforms to EN 60947-5-1 standards and carries CE and UKCA markings in accordance with applicable directives and instructions. Submit the exact part number, quantity, and application requirements for a quote.

Request pricing and availabilityCommercial response within one business day for your destination and required quantity.
Request a Quote
Why no listed price?

Industrial and obsolete parts are priced per enquiry: the final price depends on available stock, condition, quantity, and your delivery destination, so a fixed list price would be misleading. Request a quote and we confirm current pricing, lead time, and sourcing options — including hard-to-find and discontinued Festo references — within one business day.

Manufacturer
Festo
Part number
6484
Data verification
Manufacturer evidence reviewed

For a faster response, include quantity, condition, and delivery destination.

Exact part-number verificationTechnical properties are matched to 6484.
Worldwide sourcingSupport for planned and urgent industrial requirements.
Manufacturer documentationA document is added when the reviewed source provides one.

Verified configuration

Technical Specifications

Conforms to standard
EN 60947-5-1
CE marking (see declaration of conformity)
As per EU low voltage directive
UKCA marking (see declaration of conformity)
To UK instructions for electrical equipment
Measured variable
Relative pressure
Method of measurement
Pneumatic/electric pressure transducer
Operating pressure
0 MPa...0.8 MPa | 0 bar...8 bar
Max. overload pressure
12 bar
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media
Lubricated operation possible
Temperature of medium
0 °C...60 °C
Ambient temperature
0 °C...60 °C
Switching output
Contact-based
Switching function
Threshold value with xed hysteresis
Switching element function
Changeover switch
Max. switch-on point
2 bar
Min. switch-off point
0.5 bar
Max. switching frequency
1 Hz
Minimum load current
100 mA
Operating voltage range AC
12 V...250 V
DC operating voltage range
12 V...250 V
Utilization category for inductive load
AC-14 | DC-13
Utilization category for ohmic load
AC-12 | DC-12
Electrical connection
3 connecting wires
Electrical connection 1, connection technology
Open end
Cable length
0.5 m
Material of cable sheath
PVC
Type of mounting
Alternatively: | On mounting frame 1n | With through-hole
Mounting position
Any

Engineering context

Identification and RFQ Guidance

Confirm the exact configuration

Use the manufacturer part number and model code—not appearance alone. Connection, size, material, voltage, pressure, seal, and control options can differ within the same product family.

What to include in your RFQ

Provide quantity, delivery country and ZIP/postal code, required condition, target date, and photographs of the existing nameplate when available.

Technical verification

Our sourcing response is prepared against Festo 6484. Final compatibility remains subject to the machine manufacturer’s requirements and complete application data.