Global industrial sourcing · Houston, Texas info@mropartsrfq.com
Products/Festo/8036879
Festo 8036879 Flow sensor SFAW-32-S13-E-PNLK-PNVBA-M12
Reference imageConfirm configuration by manufacturer part number.

Festo

8036879

Flow sensor SFAW-32-S13-E-PNLK-PNVBA-M12

The Festo 8036879 is an industrial component utilizing vortex flow measurement and a PT1000 method to monitor unidirectional flow rate and temperature for fluid media, water, and neutral fluids. It operates within a flow measurement range of 1.8 l/min to 32 l/min, a working pressure of 0 to 12 bar, and a medium temperature range of 0 to 90 °C, featuring certifications including the RCM Mark, c UL us - Listed (OL), and KC-EMV. Compliance is maintained with the EU-EMV guideline, EU RoHS directive, and RoHS materials note, while ensuring compatibility between the operating medium and contact materials. Submit the exact part number, quantity, and application requirements for a quote.

Request pricing and availabilityCommercial response within one business day for your destination and required quantity.
Request a Quote
Why no listed price?

Industrial and obsolete parts are priced per enquiry: the final price depends on available stock, condition, quantity, and your delivery destination, so a fixed list price would be misleading. Request a quote and we confirm current pricing, lead time, and sourcing options — including hard-to-find and discontinued Festo references — within one business day.

Manufacturer
Festo
Part number
8036879
Data verification
Manufacturer evidence reviewed

For a faster response, include quantity, condition, and delivery destination.

Exact part-number verificationTechnical properties are matched to 8036879.
Worldwide sourcingSupport for planned and urgent industrial requirements.
Manufacturer documentationA document is added when the reviewed source provides one.

Verified configuration

Technical Specifications

Authorization
RCM Mark | c UL us - Listed (OL)
CE symbol (see declaration of conformity)
according to EU-EMV guideline | in accordance with EU RoHS directive
KC mark
KC-EMV
Materials note
Conforms to RoHS
Measured variable
Flow rate | Temperature
Direction of flow
Unidirectional | P1 -> P2
Measurement method
Flow: vortex | Temperature: PT1000
Flow measurement range initial value
1.8 l/min
Flow measurement range final value
32 l/min
Working pressure
0 ... 12 bar
Note on working pressure
Max. 12 bar at 40°C | Max. 6 bar at 100°C
Operating medium
Fluid media | Water | Neutral fluids
Note on operating and pilot medium
It must be ensured that the operating medium is compatible with the | materials with which it is in contact.
Medium temperature
0 ... 90 °C
Ambient temperature
0 ... 50 °C
Nominal temperature
23 °C
Accuracy of flow rate
±2% FS for flow rate <= 50% FS | ±3% of measured value for flow rate >= 50% FS
Accuracy of temperature in ± °C
2 °C
Repetition accuracy of flow rate value
< ±0.5% FS for flow rate <= 50% FS
<
±1% of measured value for flow rate >= 50% FS
Temperature co-efficient margin in ± %FS/K
typ. ±0,05%FS/K
Switch output
2 x PNP or 2 x NPN switchable
Switching function
Window comparator | Threshold value comparator | Freely programmable
Switching element function
N/C or N/O contact, switchable
Max. output current
100 mA
Analog output
0 - 10 V | 4 - 20 mA | 1 - 5 V
Characteristic curve for flow rate initial value
0 l/min
Characteristic curve for flow rate final value
32 l/min
Max. load resistance, current output
500 Ohm

Engineering context

Identification and RFQ Guidance

Confirm the exact configuration

Use the manufacturer part number and model code—not appearance alone. Connection, size, material, voltage, pressure, seal, and control options can differ within the same product family.

What to include in your RFQ

Provide quantity, delivery country and ZIP/postal code, required condition, target date, and photographs of the existing nameplate when available.

Technical verification

Our sourcing response is prepared against Festo 8036879. Final compatibility remains subject to the machine manufacturer’s requirements and complete application data.