Global industrial sourcing · Houston, Texas info@mropartsrfq.com
Products/Festo/8058516
Festo 8058516 Flow sensor SFAE-5U-Q4-PNLK-PNVB-0.3M8
Reference imageConfirm configuration by manufacturer part number.

Festo

8058516

Flow sensor SFAE-5U-Q4-PNLK-PNVB-0.3M8

The Festo part number 8058516 is an industrial component featuring a unidirectional flow measuring range from 0 l/min to 5 l/min with a 12-bit ADC resolution and 2 x PNP or 2 x NPN switchable switching outputs supporting window and threshold value comparators. It operates within a pressure range of -0.09 MPa to 1 MPa (-0.9 bar to 10 bar or -13.05 psi to 145 psi) and handles an overload pressure up to 1.6 MPa (16 bar or 232 psi) using compressed air conforming to ISO 8573-1:2010 [7:4:4] or nitrogen at medium and ambient temperatures between 0 °C and 50 °C. The unit carries RCM, CE, and UKCA compliance marks, is RoHS compliant, and features a flow rate accuracy of ± (5% o.m.v. + 2% FS). Submit the exact part number, quantity, and application requirements for an RFQ quote.

Request pricing and availabilityCommercial response within one business day for your destination and required quantity.
Request a Quote
Why no listed price?

Industrial and obsolete parts are priced per enquiry: the final price depends on available stock, condition, quantity, and your delivery destination, so a fixed list price would be misleading. Request a quote and we confirm current pricing, lead time, and sourcing options — including hard-to-find and discontinued Festo references — within one business day.

Manufacturer
Festo
Part number
8058516
Data verification
Manufacturer evidence reviewed

For a faster response, include quantity, condition, and delivery destination.

Exact part-number verificationTechnical properties are matched to 8058516.
Worldwide sourcingSupport for planned and urgent industrial requirements.
Manufacturer documentationA document is added when the reviewed source provides one.

Verified configuration

Technical Specifications

Certication
RCM compliance mark
CE marking (see declaration of conformity)
As per EU EMC directive | As per EU RoHS directive
UKCA marking (see declaration of conformity)
To UK instructions for EMC | To UK RoHS instructions
Note on materials
RoHS compliant
Flow direction
Unidirectional
Flow measuring range start value
0 l/min
Flow measuring range end value
5 l/min
Operating pressure
-0.09 MPa...1 MPa | -0.9 bar...10 bar | -13.05 psi...145 psi
Overload pressure
1.6 MPa | 16 bar | 232 psi
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4] | Nitrogen
Information on operating and pilot media
Ester oil < 0.1mg/m³, according to ISO 8573-1:2010 [-:-:2]
Temperature of medium
0 °C...50 °C
Ambient temperature
0 °C...50 °C
Nominal temperature
23 °C
ADC resolution
12 bit
Accuracy of ow rate
± (5% o.m.v. + 2% FS)
Zero point repetition accuracy in ± %FS
0.5 %FS
Repetition accuracy margin in ± %FS
1 %FS
Switching output
2 x PNP or 2 x NPN switchable
Switching function
Window comparator | Threshold value comparator
Switching element function
N/C contact/N/O contact, switchable
On time
10 ms

Engineering context

Identification and RFQ Guidance

Confirm the exact configuration

Use the manufacturer part number and model code—not appearance alone. Connection, size, material, voltage, pressure, seal, and control options can differ within the same product family.

What to include in your RFQ

Provide quantity, delivery country and ZIP/postal code, required condition, target date, and photographs of the existing nameplate when available.

Technical verification

Our sourcing response is prepared against Festo 8058516. Final compatibility remains subject to the machine manufacturer’s requirements and complete application data.