Global industrial sourcing · Houston, Texas+1 417 261 6001 info@mropartsrfq.com
Products/Festo/8158422
Festo 8158422 Flow sensor SFAH-100U-G14FS-PNLK-PNVBA-L1
Reference imageConfirm configuration by manufacturer part number.

Festo

8158422

Flow sensor SFAH-100U-G14FS-PNLK-PNVBA-L1

Festo Flow sensor SFAH-100U-G14FS-PNLK-PNVBA-L1, part number 8158422, is documented in the official Festo United States product data sheet. Review the technical specifications and operating conditions below when requesting a quotation.

Request pricing and availabilityCommercial response for your destination and required quantity.
Request a Quote
Manufacturer
Festo
Part number
8158422
Data verification
Manufacturer evidence reviewed

For a faster response, include quantity, condition, and delivery destination.

Exact part-number verificationTechnical properties are matched to 8158422.
Worldwide sourcingSupport for planned and urgent industrial requirements.
Manufacturer documentationTechnical documents are stored and served from our system.

Verified configuration

Technical Specifications

Identification and family-level technical context are preserved from reviewed source evidence and official English-language manufacturer documentation.

Certication
RCM compliance mark | c UL us - Listed (OL)
CE marking (see declaration of conformity)
As per EU EMC directive | As per EU RoHS directive
UKCA marking (see declaration of conformity)
To UK instructions for EMC | To UK RoHS instructions
Note on materials
RoHS compliant
Measured variable
Mass ow | Volumetric ow rate
Flow direction
Unidirectional
Measuring principle
Thermal
Method of measurement
Heat transfer
Flow measuring range start value
2 l/min
Flow measuring range end value
100 l/min
Operating pressure
-0.9 bar...10 bar
Operating medium
Argon | Compressed air as per ISO 8573-1:2010 [6:4:4] | Nitrogen
Temperature of medium
0 °C...50 °C
Ambient temperature
0 °C...50 °C
Nominal temperature
23 °C
Accuracy of ow rate
± (2% o.m.v. + 1% FS)
Zero point repetition accuracy in ± %FS
0.2 %FS
Repetition accuracy margin in ± %FS
0.8 %FS
Temperature co-efficient margin in ± %FS/K
typ. 0.15%FS/K
Pressure inuence of margin in ±%FS/bar
1 %FS/b.
Switching output
2 x PNP or 2 x NPN switchable
Switching function
Window comparator | Threshold value comparator | Auto difference monitoring
Switching element function
N/C contact/N/O contact, switchable
Max. output current
100 mA
Analog output
0 - 10 V | 4 - 20 mA

Technical library

Documents and Data Sheets

Engineering context

Identification and RFQ Guidance

Confirm the exact configuration

Use the manufacturer part number and model code—not appearance alone. Connection, size, material, voltage, pressure, seal, and control options can differ within the same product family.

What to include in your RFQ

Provide quantity, delivery country and ZIP/postal code, required condition, target date, and photographs of the existing nameplate when available.

Technical verification

Our sourcing response is prepared against Festo 8158422. Final compatibility remains subject to the machine manufacturer’s requirements and complete application data.